Test Variables
- Resistance at the beginning of the test [Ω]: 15.39
- Ambient temperature [°C]: 24
- Coefficient of temperature: 0.0038684719535783366
- Uncertainty of initial time [s]: 1
- Uncertainty of acquisition time [s]: 0.001
- Uncertainty of resistance measurement [Ω]: 0.001
- Uncertainty of ambient temperature measurement [°C]: 0.1
- Number of Monte Carlo simulations: 1000
Model comparison
Mean and Std values
| Model Type |
Degree |
SSE [Ω²] |
Resistance [Ω] |
Resistance estimation uncertainty [Ω] |
Temperature [°C] |
| poly |
1 |
14853 ± 245.92 |
19.426 ± 0.027441 |
0.015239 ± 0.00058182 |
91.794 ± 0.47211 |
| poly |
2 |
159.39 ± 22.717 |
19.522 ± 0.039236 |
0.0029645 ± 0.00036132 |
93.396 ± 0.66692 |
| poly |
3 |
54.149 ± 13.073 |
19.535 ± 0.04227 |
0.0031205 ± 0.00065375 |
93.629 ± 0.71732 |
| poly |
4 |
42.748 ± 11.571 |
19.543 ± 0.044562 |
0.0051002 ± 0.0015135 |
93.76 ± 0.75544 |
| exp |
0 |
60.046 ± 13.463 |
19.533 ± 0.04174 |
0.050219 ± 0.0020417 |
93.588 ± 0.70852 |